SHOP FOR
http://base-store.storehippo.com/
# 2514/U, 7th 'A' Main Road, Opp. to BBMP Swimming Pool, Hampinagar, Vijayanagar 2nd Stage. 560104 Bangalore IN
Tenettech E-Store
# 2514/U, 7th 'A' Main Road, Opp. to BBMP Swimming Pool, Hampinagar, Vijayanagar 2nd Stage. Bangalore, IN
+918023404924 //cdn1.storehippo.com/s/59c9e4669bd3e7c70c5f5e6c/ms.settings/5256837ccc4abf1d39000001/webp/59dafe26aef6e1d20402c4c3-480x480.png" info@tenettech.com
6043495a8b3a28c2c455cb5f Board Mount Current Sensors Current Sensor 200A pri open +/-15V //cdn1.storehippo.com/s/59c9e4669bd3e7c70c5f5e6c/6043495a8b3a28c2c455cb61/webp/4646-x201.png

Current Sensors

Vacuumschmelze (VAC) Current Sensors utilize amorphous field detector technology which makes the sensor more accurate and also improves linear performance with changes in temperature. The main function of VAC Current Sensors is measuring currents from DC up to high frequencies (approximately 200kHz).  These sensors contain a galvanic separation between the primary circuit and the output signal (according to EN 50178 or EN 61800) and typical currents range from a few amperes up to several hundred amperes full range. Some sensor types can measure more than 1000 ampere peak current. The accuracy of the VAC current sensors lies in the range of <1% of the nominal current. The VAC-invented measuring principle of the closed-loop sensor with magnetic probe as a zero field detector is distinguished by maximum precision of the current detection. The detected currents range from 6Arms to 700Arms.

TT-MU-983-T60404-N4646X201
in stockINR 8029.79144
Vacuumschmelze
1 1
Board Mount Current Sensors Current Sensor 200A pri open +/-15V

Board Mount Current Sensors Current Sensor 200A pri open +/-15V

Sku: TT-MU-983-T60404-N4646X201
₹8,029.79


Sold By: tenettech
Features
  • Shipping in 10-12 Working Days

Description of product

Current Sensors

Vacuumschmelze (VAC) Current Sensors utilize amorphous field detector technology which makes the sensor more accurate and also improves linear performance with changes in temperature. The main function of VAC Current Sensors is measuring currents from DC up to high frequencies (approximately 200kHz).  These sensors contain a galvanic separation between the primary circuit and the output signal (according to EN 50178 or EN 61800) and typical currents range from a few amperes up to several hundred amperes full range. Some sensor types can measure more than 1000 ampere peak current. The accuracy of the VAC current sensors lies in the range of <1% of the nominal current. The VAC-invented measuring principle of the closed-loop sensor with magnetic probe as a zero field detector is distinguished by maximum precision of the current detection. The detected currents range from 6Arms to 700Arms.